Commercial Roofing Systems for North Texas Buildings

Commercial roofing systems for North Texas buildings

A commercial roof decision gets made badly more often than a residential one, and usually for the same reason.

The building owner is handed three bids that quote three different systems, with no explanation of why any of them suits this particular building. The numbers are compared. The lowest one wins. Six years later the roof is a line item in a capital budget that was supposed to cover something else.

The useful conversation starts earlier, with what the building actually has to survive.

What a North Texas roof is up against

Four things, in roughly this order.

Hail. The DFW corridor takes damaging hail regularly. On a low-slope roof, hail shows up as bruising, membrane fracture and punctures that may not leak for a year.

Heat and UV. Rooftop surface temperatures here run far above air temperature through the summer, for months. UV degrades membranes and dries out asphaltic products.

Thermal cycling. Big daily swings, especially in spring and fall, mean the assembly expands and contracts constantly. That movement finds seams, fasteners and flashings.

Wind uplift. Less dramatic than hail, but it governs how the system must be attached, and attachment is where a lot of failures actually originate.

Any system can be specified to handle all four. The question is whether the one you were quoted was.

The systems, honestly compared

TPO. A single-ply thermoplastic membrane, usually white, with heat-welded seams. It is the most common low-slope choice in this market for good reasons. The reflectivity genuinely helps with heat, the welded seams are strong, and the material cost is reasonable.

The thing to watch is thickness. TPO is sold in different mil thicknesses, and a thin membrane over a hail-prone building is a short-term decision. If a bid does not state the thickness, that is the first question to ask.

PVC. Also single-ply and heat-welded, generally more expensive than TPO, with better resistance to grease and chemicals. Worth the premium on restaurants and some manufacturing. Overkill on a warehouse.

EPDM. A rubber single-ply, usually black. Durable and flexible, with a long track record. The reflectivity disadvantage in a Texas summer is real, and white EPDM narrows the gap at added cost. It makes more sense in colder markets than in this one.

Modified bitumen. Asphaltic membrane applied in multiple plies. The multi-ply build gives it genuine puncture and impact resistance, which is a meaningful advantage in a hail market. It is heavier and installation is more involved.

Built-up roofing. The traditional multi-ply tar and gravel assembly. Tough and long-lived when done well, and still a legitimate answer on the right building, though less commonly specified on new work.

Metal. Standing seam systems last a long time and handle water beautifully on sloped commercial buildings. Hail will dent panels. Whether that matters depends on whether anyone can see the roof and how your policy treats cosmetic damage, which is worth asking your carrier before you choose.

Coatings and restoration. A fluid-applied coating over a sound existing roof can extend service life meaningfully at a fraction of replacement cost. The word doing the work there is sound. A coating over a wet or failing assembly buys a year and hides the evidence. It is a legitimate strategy and a common way to waste money, depending entirely on condition.

Drainage decides more than the membrane does

Low-slope does not mean flat, and the distinction is where buildings get into trouble.

Standing water accelerates the breakdown of nearly every membrane, adds weight the structure was not designed for, and turns a small puncture into an interior problem. Ponding that remains two days after rain is a condition worth fixing, not accepting.

The fixes are not glamorous. Tapered insulation to build positive slope. Additional drains. Cleaning the drains that exist, which is the cheapest roofing work anyone will ever do and the most frequently skipped.

If a bid quotes a membrane without addressing drainage on a building that ponds, the bid is incomplete regardless of the price.

Reading a commercial bid

A few things separate a real proposal from a number on letterhead.

Tear-off or recover? Going over an existing roof is cheaper. It is also limited by code and by what is underneath. If moisture is trapped in the existing assembly, a recover seals the problem in.

What is the insulation and what is the R-value? Insulation is a significant part of the cost and of the long-term energy performance. Bids that leave it vague are usually vague for a reason.

How is it attached? Mechanically fastened, fully adhered, or ballasted. This drives wind performance.

What kind of warranty? A manufacturer’s no-dollar-limit system warranty is a different product than a material-only warranty plus a contractor workmanship warranty. Both have their place. They are not comparable, and bids routinely present them as though they are.

Who handles the details? Flashings, curbs, penetrations, edge metal. Most leaks are not in the field of the roof. They are at the transitions.

Hail claims on a commercial building

If you carry commercial property insurance in this area, you will eventually file a storm claim.

Two Texas rules that apply to residential claims apply to yours as well. A contractor cannot offer to waive, rebate or absorb your deductible, and a contractor who is doing the work cannot act as your public insurance adjuster. The Texas Department of Insurance lays both out on its roofing and insurance page.

Commercial deductibles are frequently a percentage of insured value rather than a flat dollar amount, which makes them large. That makes the illegal offer more tempting and more dangerous.

What a contractor can legitimately do is document the damage thoroughly, meet your adjuster on the roof, and provide a scope that reflects what the building actually needs.

Vetting a commercial roofer

Texas does not license roofing contractors at the state level, so the usual credential check does not exist here. We went through the alternatives in how to vet a roofer when Texas has no license.

For commercial work, two additional filters matter.

Insurance limits should be commercial-grade. The Roofing Contractors Association of Texas requires $500,000 in general liability for commercial applicants to its voluntary credential, compared with $300,000 for residential. Treat that as a floor to ask about, and confirm your own requirements with your risk manager.

And ask for commercial references on comparable buildings. A company that does excellent residential work has not necessarily detailed a curb or specified a tapered system.

Start with condition, not with a system

The right first step on almost any commercial building is an assessment rather than a bid.

What is up there now, how many layers, where is it holding water, what condition are the flashings and drains in, and is there moisture in the assembly. Those answers determine whether you are looking at a repair, a coating, a recover or a tear-off, and that decision is worth far more than shaving a few percent off a membrane price.

Texas Roofing Project handles commercial roofing across Garland and the North Texas metroplex. If you want a straight assessment of what your building has and what it needs, call 214-600-7661 or get in touch.

This post is general information, not engineering, legal or insurance advice. Code requirements, manufacturer specifications and policy terms vary. Confirm specifics with your design professional, your carrier and your local building department.

Written by

Steve Madison Jr., Co-Founder, Texas Roofing Project

Steve has over 12 years of construction experience, from restoration to roofing. A Texas A&M graduate, husband, and father of four, he built his career on genuine relationships and solving real problems for homeowners across North Texas. Read our story.

Explore More